HCL Analyzer HCL-103
HCL Concentration in exhaust gas, which is discharged from buming up equipment of urban waste, is attracting the attention. HCL is generated from combustion decomposition of organ chlorine compounds such as vinyl chloride pl

HCL Analyzer is designed for measuring HCL concentration of HCL, serially and automatically, which is discharged from burning up equipment of urban waste based on the law of air pollution prevention. This analyzer executes the sampling of the fixed flow automatically, by micro computer control. In addition, the analyzer measures HCL in exhaust gas by quantifying chroline ion concentration of HCL by ion selective electrodes after absorbing HCL in the gass into the absorption liquid.

To discharge the pollutant exhausted from chimney pursuant to the standard of allowable exhaust, HCL Analyzer in TMS is used by regulating the diluted amount of pollutants in accordance with the concentration values indicated on the measuring instrument in link of nitrogen oxide and HCL. As Ministry of Environment has controlled HCL concentration values by lowering them continuously and will control the total discharge amount, higher accuracy and safety of the data values are required.

By the technology acquiring accurate and stable data values in reducing cost of waste incineration company and in transmitting data to Environment Corporation, exhaust concentration of air pollution can be reflected correctly, and also be contributed to the establishment of the policy against environmental pollution by the government.

Features of HCL

  • Metal film electrode is applied to detecting element, so it has better reproducibility and reliability than the devices that use the existing rod electrode or magnetic stirrer type polishing electrode.
  • Detecting element has temperature regulation function in its interior, so it is not affected from external temperature or chimney.
  • Drainage of absorbed reagent is serially executed using tube pump.
  • Sample gas amount is measured and auto-controlled by pressure sensor, so it is accurately absorbed by automatic digital control even in pressure changing of smoke tube.
  • It always operates automatic measuring of analysis liquid, and is not affected from moisture in exhaust gas.
  • It has high reliability of data, because checking the sensibility can be made every day by automatic sensitivity check and auto-calibration mechanism.
  • It can display rate value, one-hour mean value, one-day mean value, and error by micro computer control.
  • This is the system to make accurate measurement of electrode radical ion by removing noncontact section of electrode and liquid by bubble at unit area of measurement electrode of electrode radical ion.
  • This is wastewater-air treatment system that has the advantage of separating gas and liquid smoothly, since it makes gas and liquid mixed smooth by gas-liquid mixing concave section at the upper part of gas-liquid separator.

Specifications

Measurement Object
HCL gas in chimney exhaust gas
Measurement Type
24-hour sequence automatic measurement
Structure
Indoor Independent type(standar)
(Option: Outdoor Independent type, Non-explosive watertight structure)
Measurement Range
0-20/50/150ppm
Measurement Method
Chloride Ion Electrode method
Repeatability
within ±2%FS(by equivalent liquid)
Zero Drift
within ±2%FS/Day(by equivalent liquid)
Span Drif
within ±2%FS/Day(by equivalent liquid)
Response Speed
Within 5 min. of 90% response (by equivalent liquid)
Sample Flow rates
500mL/min
Sample Tube Length
Standard 10m
Absorption Liquid
20L(replacement by 1 time/2weeks)
Liquid Flow Amount
Approx. 0.8mL/min
Display
Measurement value, time and measurement mode, etc.
Calibration method
2-point calibration by equivalent liquid, Manual/Auto, Remote
External Input
4-20mA DC
Contact Signal Output
Power cut-off, in regulating, malfunction, abnormal concentration and close contact output
Coated Color-Main body
Manin body:5Y7/1, CELL: Black
CPU:5Y7/1
Power
AC 110V/220V 60Hz
Electricity Consumption
400VA(Main body and Porbe are included)


Product Image

  • Cl - Ion Electrode Method HCl Analyzer image

Related products from premium suppliers on EC21

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Gi-yeol Jeon
Kusung Technics Co., Ltd.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Other Measuring & Gauging Tools
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838